{"product_id":"e-mem-8040-industrial-ro-membrane","title":"LP\/ULP22-8040 Vontron Industrial RO Membrane","description":"\u003ch3 style=\"text-align: left;\"\u003eVontron Membranes\u003c\/h3\u003e\n\u003cp style=\"text-align: left;\"\u003eULP series of ultra-low pressure aromatic polyamide compound membrane element newly developed by Vontron Membrane Technology Co., Ltd. can work under ultra low pressure to reach as high permeate flow and rejection same as regular low-pressure membrane element, and is applicable to desalination of surface water and underground water. It operates under approximately two thirds of the operating pressure of regular low-pressure composite membranes, which can decrease the investment costs for such relevant facilities as pumps, pipelines, and containers, etc. and the operating cost for the RO system, thus increasing the economic efficiency.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eApplicable to desalination treatment of those water sources with NaCl lower than 2000 ppm, such as surface water, underground water, tap water and municipal water, ULP series membrane elements are mainly applicable to such as pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production.\u003c\/p\u003e\n\u003cp\u003eThe LP (low pressure) series of aromatic polyamide compound membrane element developed by Vontron Membrane Technology Co., Ltd. has the properties of low-pressure operation, high permeate flow and excellent desalination and is applicable to desalination of brackish water. Besides, it is particularly applicable to fabrication of high-purity water for electronic industry and electric power industry owing to its excellent performance in removing soluble salts, TOC, SiO2, etc.\u003c\/p\u003e\n\u003cp\u003eBeing suitable for desalting such water sources as surface water (NaCl ≤10000ppm), underground water, tap water and municipal water, etc., LP series is mainly applicable to treatment of various industrial water such as industrial-purpose pure water, boiler water replenishment in power plants, and can be also applied to such brackish water applications, such as treatment of high-concentration saline waste water and production of beverage-purpose water.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eDomestic Water Treatment\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eCommercial Water Treatment\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eIndustrial Water Treatment\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003ePerformance parameters of the membrane element\u003c\/h3\u003e\n\u003ctable width=\"100%\" cellspacing=\"0\" cellpadding=\"10\" align=\"left\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eActive Membrane\u003cbr\u003eArea\u003cbr\u003eft\u003csup\u003e2\u003c\/sup\u003e(m\u003csup\u003e2\u003c\/sup\u003e)\u003c\/td\u003e\n\u003ctd\u003eAverage Permeate\u003cbr\u003eGPD(m\u003csup\u003e3\u003c\/sup\u003e\u003cbr\u003e\/d)\u003c\/td\u003e\n\u003ctd\u003eStable Rejection\u003cbr\u003eRate %\u003c\/td\u003e\n\u003ctd\u003eMin. Rejection\u003cbr\u003eRate %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLP22-8040\u003c\/td\u003e\n\u003ctd\u003e400（37.2）\u003c\/td\u003e\n\u003ctd\u003e10500（39.7）\u003c\/td\u003e\n\u003ctd\u003e99.5\u003c\/td\u003e\n\u003ctd\u003e99.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting\u003cbr\u003eConditions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTesting Pressure\u003cbr\u003eTesting Solution Temperature\u003cbr\u003eConcentration of Testing Solution (NaCl)\u003cbr\u003epH value of Testing Solution\u003cbr\u003eRecovery Rate of Single Element\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e225 psi (1.55Mpa)\u003cbr\u003e25˚C\u003cbr\u003e2000ppm\u003cbr\u003e7.5\u003cbr\u003e15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Limits \u0026amp;\u003cbr\u003eConditions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax. Working Pressure\u003cbr\u003eMax. Temperature of Feed water\u003cbr\u003eMax. Volume of Feed water\u003cbr\u003eMax. Feed water SDI\u003csub\u003e15\u003c\/sub\u003e\u003cbr\u003epH Range of Feed water during Continuous Operation\u003cbr\u003epH Range of Feed Water during Chemical Cleaning\u003cbr\u003eResidual Chlorine Concentration of Feed Water\u003cbr\u003eMax. Pressure Drop of Single Membrane Element\u003cbr\u003eMax. Pressure Drop of Single Pressure Vessel with Six RO Membranes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600psi（4.14Mpa）\u003cbr\u003e45˚C\u003cbr\u003e75gpm (17\u003csup\u003e3\u003c\/sup\u003e\/h)\u003cbr\u003e5\u003cbr\u003e2~11\u003cbr\u003e1~13\u003cbr\u003e\u0026lt;0.1ppm\u003cbr\u003e15psi (0.1Mpa)\u003cbr\u003e50psi (034Mpa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\" cellspacing=\"0\" cellpadding=\"10\" align=\"left\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eActive Membrane\u003cbr\u003eArea\u003cbr\u003eft\u003csup\u003e2\u003c\/sup\u003e(m\u003csup\u003e2\u003c\/sup\u003e)\u003c\/td\u003e\n\u003ctd\u003eAverage Permeate\u003cbr\u003eGPD(m\u003csup\u003e3\u003c\/sup\u003e\u003cbr\u003e\/d)\u003c\/td\u003e\n\u003ctd\u003eStable Rejection\u003cbr\u003eRate %\u003c\/td\u003e\n\u003ctd\u003eMin. Rejection\u003cbr\u003eRate %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eULP22-8040\u003c\/td\u003e\n\u003ctd\u003e400（37.2）\u003c\/td\u003e\n\u003ctd\u003e12100（45.7）\u003c\/td\u003e\n\u003ctd\u003e99.0\u003c\/td\u003e\n\u003ctd\u003e98.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting\u003cbr\u003eConditions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTesting Pressure\u003cbr\u003eTesting Solution Temperature\u003cbr\u003eConcentration of Testing Solution (NaCl)\u003cbr\u003epH value of Testing Solution\u003cbr\u003eRecovery Rate of Single Element\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e150 psi (1.55Mpa)\u003cbr\u003e25˚C\u003cbr\u003e1500ppm\u003cbr\u003e7.5\u003cbr\u003e15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Limits \u0026amp;\u003cbr\u003eConditions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax. Working Pressure\u003cbr\u003eMax. Temperature of Feed water\u003cbr\u003eMax. Volume of Feed water\u003cbr\u003eMax. Feed water SDI\u003csub\u003e15\u003c\/sub\u003e\u003cbr\u003epH Range of Feed water during Continuous Operation\u003cbr\u003epH Range of Feed Water during Chemical Cleaning\u003cbr\u003eResidual Chlorine Concentration of Feed Water\u003cbr\u003eMax. Pressure Drop of Single Membrane Element\u003cbr\u003eMax. Pressure Drop of Single Pressure Vessel with Six RO Membranes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600psi（4.14Mpa）\u003cbr\u003e45˚C\u003cbr\u003e75gpm (17\u003csup\u003e3\u003c\/sup\u003e\/h)\u003cbr\u003e5\u003cbr\u003e3~10\u003cbr\u003e2~12\u003cbr\u003e\u0026lt;0.1ppm\u003cbr\u003e15psi (0.1Mpa)\u003cbr\u003e50psi (034Mpa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecification And Size\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.puritech.co.za\/wp-content\/uploads\/2021\/03\/Screenshot-2021-03-19-at-13.36.31.png\" alt=\"\" width=\"2132\" height=\"602\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e(A)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.puritech.co.za\/wp-content\/uploads\/2021\/03\/Screenshot-2021-03-19-at-13.36.51-1024x372.png\" alt=\"\" width=\"895\" height=\"325\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e(B)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003eHow An RO Membrane Is Made\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eBelow is a video that explains how an RO membrane is made\u003c\/p\u003e\n\u003cp\u003ehttps:\/\/youtu.be\/c640QM5Ccyw\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003eHow An RO Membrane Works\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eBelow is a video that explains how an RO membrane works\u003c\/p\u003e\n\u003cp\u003ehttps:\/\/youtu.be\/jOYZWPhjUI4\u003c\/p\u003e","brand":"Pure Drop Technicals","offers":[{"title":"Default Title","offer_id":45462479863998,"sku":"LP\/ULP22-8040","price":12000.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/2268\/5886\/files\/8040-industrial-reverse-osmosis-membrane_27a14646-25e3-4403-8f4c-772f88e47d5d.jpg?v=1759881981","url":"https:\/\/www.watershopinstallations.co.za\/products\/e-mem-8040-industrial-ro-membrane","provider":"Pure Drop Technicals","version":"1.0","type":"link"}